Rock Tech Provides Update on Georgia Lake Program
Tuesday, 01 February 2011 09:16 AM
Vancouver, British Columbia, Canada, February 1, 2011 - Rock Tech Lithium Inc. (TSX-Venture: RCK; Frankfurt: RJIA) (the "Company" or "Rock Tech") is pleased to announce that its drill program at its Georgia Lake is progressing as scheduled.
Drilling recommenced on January 9, 2011 following the Christmas break. A total of 11 drill holes have been completed to date with 1,268 metres diamond core drilling, of which 3 drill holes were completed before the Christmas break. A second drill rig has been mobilized to the site to expedite drilling and subsequent NI 43-101 compliant resource estimation. The Company is on target to complete 4,000 metres of diamond core drilling by the end of February 2011. Bulk sample for metallurgical testing will be collected in the second week of February and will be tested to produce battery quality lithium carbonate by the end of May 2011.
The three dimensional modeling of the Nama Creek deposit has been completed by Caracle Creek International Consulting ("CCIC"). The visual model is available on the Company's website, http://www.rocktechlithium.com/properties/georgia-lake-nw-ontario/3d-models. The 3D models for the other deposits at Georgia Lake are currently being developed, and as they are completed, they will be posted on the Company's website. The results of the environmental baseline study will be available by mid-February 2011, and further environmental field work will be conducted in the spring of 2011, with results to follow 2 months thereafter. The Company is on target for delivery of NI 43-101 compliant resource estimate by June 2011.
Drill hole summary based on drill logs is provided in the following table.
-------------------------------------------------------------------- |Drill Hole | |Summary | |Georgia | |Lake | |Lithium | |Project | |Exploration | |2010-11 | |------------------------------------------------------------------| |Drill Hole|Pegmatite Dyke Name |Azimuth |Dip (angle)|Total depth| |ID | |(degrees)| |(m) | |------------------------------------------------------------------| |CW11-01 |Conway |121 |-55 |169.70 | |------------------------------------------------------------------| |CW11-02 |Conway |128 |-55 |130.83 | |------------------------------------------------------------------| |CW11-03 |Conway |119 |-55 |101.00 | |------------------------------------------------------------------| |CW11-04 |Conway |120 |-55 |154.30 | |------------------------------------------------------------------| |L6-11-01 |Nama Creek (Line 60) |102 |-55 |125.00 | |------------------------------------------------------------------| |L6-11-02 |Nama Creek (Line 60) |102 |-55 |160.70 | |------------------------------------------------------------------| |HW11-01 |Nama |94 |-55 |122.00 | | |Creek | | | | | |Harricana | | | | | |West | | | | |------------------------------------------------------------------| |HW11-02 |Nama |104 |-55 |173.40 | | |Creek | | | | | |Harricana | | | | | |West | | | | |------------------------------------------------------------------| |AM10-1 |Aumacho |110 |-50 |71.00 | |------------------------------------------------------------------| |AM10-02 |Aumacho |140 |-50 |58.75 | |------------------------------------------------------------------| |AM10-03 |Aumacho |150 |-50 |70.65 | --------------------------------------------------------------------
Caution: The spodumene contents in the pegmatite dykes are estimates and may not directly correlate with lithium oxide grades. Assay results are pending. (source: Caracle Creek International Consulting)
Eunho Lee commented, "Most of the drill holes at Nama Creek and Conway were placed within close proximity of spodumene bearing pegmatite zones that were intersected in historical drill holes. We are very encouraged by the drill log data provided by CCIC as they confirm the historical drill core data from these areas. Pegmatite zone ranges in thickness from 2.85 metres to 21.08 metres, with spodumene content of <3% to 15%. We are now patiently and anxiously waiting for chemical assay results to be returned to us so that we can confirm lithium oxide grades."
Quality Assurance and Quality Control Methods
Drill cores are being logged by CCIC's geological team utilizing strict quality control procedures for core handling, measuring, observation recording and sample shipping to the laboratories. When core has been logged, the section to be sampled are split and bagged; and 10% standards, blanks and duplicates are inserted in each batch shipped to SGS Mineral Services laboratories in Toronto which is a Canadian ISO 17025 accredited laboratory. The retained halves of the split core are replaced in their original boxes and stored. The samples are being assayed using ICM 90A package for multi elemental analysis by sodium peroxide fusion/ICP-AES and ICP-MS analysis, and whole rock analysis using XRF76C (Meta-Tetraborate fusion / XRF analysis). Selected samples from pegmatites and the host rocks are also being tested for specific gravity using method PHY03B - Air Picnometer which will be used for resource estimation.
Based on historical exploration data, the Nama Creek 3 dimensional model created by CCIC is ready and is being used for future drill hole planning. The drill holes are being placed either to twin a historical drill hole or to fill the data gap.
Technical information of this news release has been reviewed by Afzaal Pirzada, P.Geo., Vice President, Exploration of the Company and a Qualified Person as defined in NI43-101.
ON BEHALF OF THE BOARD OF DIRECTORS
"Eunho Lee"
Eunho Lee
Director, President and CEO
For more information, please contact:
Brad Barnett
Controller and Senior Manager, Business Affairs
Rock Tech Lithium Inc.
789 West Pender Street, Suite 1205
Vancouver, B.C., V6C 1H2
Telephone: (604) 688-1140
Facsimile: (604) 688-1173
Email: [email protected]
Disclaimer and Cautionary Statement Regarding Forward-Looking Information
Neither the TSX Venture Exchange nor its Regulation Services Provider (as that term is defined in the policies of the TSX Venture Exchange) accepts responsibility for the adequacy or accuracy of this press release. This news release shall not constitute an offer to sell or the solicitation of an offer to buy securities in any jurisdiction. The spodumene contents in the pegmatite dykes as reported in this press release are estimates and may not directly correlate with lithium oxide grades. Assay results are pending.
