Argonaut Exploration Inc. Samples Widespread Surface and Underground Gold to 72 Grams per Tonne at Terrace, B.C.

Monday, 24 October 2011 09:28 AM

Calgary, Alberta, October 24th, 2011, Argonaut Exploration Inc. TSX-V; AGA ("Argonaut" or "the Company") is pleased to release the Company's 2011 exploration program chip and channel sample results from surface outcrops and underground workings at the Columario property, Terrace, British Columbia (Table 1, 2 and 3).

The objective of the 2011 field program was to explore, through geologic mapping, rock sampling and diamond drilling, the historically documented vein systems reported from the Columario property and mine. Argonaut's 2011 program included re-building the overgrown and damaged 2.8 kilometre (km) access road to the mine portals. Re-building the road puts the mine workings 1.6 km from the nearest power line, 6 km from the road junction with the Yellowhead Highway and 18 km from the City of Terrace.

Six separate veins were sampled during the 2011 exploration program. The veins sampled are historic veins 4, 5, 6, 7, the Tenderfoot vein and the Victor vein. With the exception of vein 5, 100% of the vein sample results are posted in the contained tables. The veins were all sampled at surface in outcrop with the exception of vein 7 which was sampled underground.

TABLE 1. COLUMARIO MINE: ROAD VEIN CHANNEL SAMPLES


----------------------------------------------------------------------
|Sample  |Sample Type  |Location   |Vein|Elevation|Width |Au   |Ag   |
|Number  |             |(West to   |    |(m)      |(m)   |(g/t)|(g/t)|
|        |             |East)      |    |         |      |     |     |
|--------------------------------------------------------------------|
|G0750891|chip/channel |Adit 5,    |4   |655      |0.7   |37.0 |103.0|
|        |             |Site 1     |    |         |      |     |     |
|--------------------------------------------------------------------|
|        |             |           |    |         |      |     |     |
|--------------------------------------------------------------------|
|G0750895|chip/channel |Adit 5,    |4   |655      |1.55  |2.3  |7.4  |
|G0750896|             |Site 2     |    |         |      |     |     |
|--------------------------------------------------------------------|
|G0750896|Including    |Adit 5,    |4   |655      |0.8   |2.68 |7.7  |
|        |             |Site 2     |    |         |      |     |     |
|--------------------------------------------------------------------|
|        |             |           |    |         |      |     |     |
|--------------------------------------------------------------------|
|G0750898|chip/channel |Adit 4,    |4   |630      |1.25  |10.6 |28.1 |
|G0750899|             |Site 1     |    |         |      |     |     |
|--------------------------------------------------------------------|
|G0750898|Including    |Adit 4,    |4   |630      |0.35  |36.4 |93.7 |
|        |             |Site 1     |    |         |      |     |     |
|--------------------------------------------------------------------|
|        |             |           |    |         |      |     |     |
|--------------------------------------------------------------------|
|G0750885|chip/channel |Adit 3,    |5*  |630      |0.9   |2.34 |20.2 |
|        |             |Site 2     |    |         |      |     |     |
|--------------------------------------------------------------------|
|        |             |           |    |         |      |     |     |
|--------------------------------------------------------------------|
|G0750878|chip/channel |Adit 2,    |6   |640      |0.85  |1.39 |4.8  |
|G0750879|             |Site 1     |    |         |      |     |     |
|        |             |Dakota adit|    |         |      |     |     |
|--------------------------------------------------------------------|
|G0750878|Including    |Adit 2,    |6   |640      |0.25  |2.6  |9.4  |
|        |             |Site 1     |    |         |      |     |     |
|--------------------------------------------------------------------|
|        |             |           |    |         |      |     |     |
|--------------------------------------------------------------------|
|G0750897|chip/channel |Adit 11,   |?   |550      |0.35  |10.9 |32.6 |
|        |             |Site 1     |    |         |      |     |     |
|        |             |Tenderfoot |    |         |      |     |     |
|        |             |Adit       |    |         |      |     |     |
|        |             |           |    |         |      |     |     |
|        |             |@ 338 m NNE|    |         |      |     |     |
|        |             | from      |    |         |      |     |     |
|        |             |Dakota     |    |         |      |     |     |
|        |             |portal     |    |         |      |     |     |
----------------------------------------------------------------------

*Vein 5 yielded only one significant gold value from four samples taken at three sites.

The historic Columario mine is located on veins 4, 5 and 6 (Dakota vein) with vein 7, Tenderfoot, Victor and several other veins peripheral to the mine workings. Vein 4 is the only vein developed over three separate levels, approximately 25 meters (m) vertically apart along adits 4, 5 and 6. The location of sampled veins external to the Columario mine include vein 7 at 84 m northeast of the mine, Tenderfoot vein at 338 m north-northeast and the Victor vein at 2.1 km to the south. The adit numbers and vein numbers are independent of each other.

Surface mapping in the mine area indicates that the Columario veins occupy a series of sub-parallel, en echelon fault structures that trend northwest to southeast (NW - SE) and dip moderately at 35 to 65 degrees to the northeast (NE). The horizontal distance from vein 4 to the Tenderfoot vein is approximately 380 m to the NE and 105 m lower in elevation. The greatest strike distance between a surface vein outcrop and the same vein's underground exposure is 150 m.

Vein 7

Vein 7 was targeted for underground sampling due to the adit's accessibility and absence of an historic sample record. Vein 7 was known to have been selectively high-graded in 1939, and Argonaut wanted to determine if significant gold remained in the adit. All of the vein 7 sample results are documented in Table 2.

TABLE 2. VEIN 7: TOTAL UNDERGROUND VEIN SAMPLES


------------------------------------------------------------
|Sample  |Sample Type|Location          |Width |Au   |Ag   |
|Number  |           |(Elevation 628 m) |(m)   |(g/t)|(g/t)|
|----------------------------------------------------------|
|G0750919|Chip sample|Portal            |0.5   |7.16 |16.8 |
|----------------------------------------------------------|
|G0750920|Chip sample|5 m from portal   |0.5   |16.1 |7.8  |
|----------------------------------------------------------|
|G0750921|Chip sample|5 m from portal   |0.3   |22.3 |21.9 |
|----------------------------------------------------------|
|G0750923|Chip sample|8 m from portal   |0.42  |31.7 |35.9 |
|----------------------------------------------------------|
|G0750925|Chip sample|11 m from portal  |1.0   |8.88 |20.3 |
|----------------------------------------------------------|
|G0750926|Chip sample|12 m from portal  |0.13  |18.9 |16.0 |
|----------------------------------------------------------|
|G0750928|Chip sample|14.5 m from portal|0.36  |0.34 |1.3  |
|----------------------------------------------------------|
|G0750930|Chip sample|17 m from portal  |0.15  |50.6 |143.0|
|----------------------------------------------------------|
|G0750931|Chip sample|17 m from portal  |0.5   |8.05 |11.3 |
|----------------------------------------------------------|
|G0750933|Chip sample|18.5 m from portal|0.18  |38.6 |51.8 |
|----------------------------------------------------------|
|G0750936|Chip sample|20 m from portal  |0.16  |24.5 |67.6 |
------------------------------------------------------------

The 2011 Columario program included the generation of a 5-year work permit directed at surface and underground exploration on the property. Argonaut initiated, in July, an underground evaluation process utilizing contractor Genex Mining Company Ltd (Genex). Genex and geology consultants Ridgeview Resources Ltd. accessed and examined the air quality and safety condition of adits 1, 2, 3 and 8. The Company's current underground plan, which is dependent on additional financing, is to re-habilitate adit 3 and conduct underground drilling to assess the economic gold potential of adjacent veins.

Victor Vein

The Victor vein is located 2.1 km south of the Columario mine workings, on the north flank of Kleanza Mountain, at an elevation ranging from 1,152 m to 1,225 m. The Victor and associated veins were historically described as the potential extension of the Columario mine vein system. The vein is exposed intermittently over a strike length of 150 m with an average width of approximately 0.5 m. The host rock is lower Jurassic Hazelton volcanic andesite, the same as that exposed with diorite at the Columario mine. The vein quartz weathers resistantly from the volcanics and is easily explored in the higher alpine setting. The vein appears to be faulted at both ends requiring additional exploration to determine its projected offsets.

TABLE 3. TOTAL VICTOR VEIN ROCK SAMPLES


------------------------------------------------------------------
|Sample  |Description |Location     |Elevation|Width |Au   |Ag   |
|Number  |            |             |(m)      |(m)   |(g/t)|(g/t)|
|----------------------------------------------------------------|
|G0750909|chip/channel|Portal, vein |1152     |0.7   |0.92 |1.2  |
|        |            |adit         |         |      |     |     |
|----------------------------------------------------------------|
|G0750910|chip/channel|4.5 m north  |1152     |0.55  |46.4 |6.3  |
|        |            |from         |         |      |     |     |
|        |            |G0750909     |         |      |     |     |
|----------------------------------------------------------------|
|G0750911|chip/channel|23 m south of|1165     |0.3   |0.38 |0.75 |
|        |            |portal       |         |      |     |     |
|----------------------------------------------------------------|
|G0750912|chip/channel|40 m south of|1180     |0.5   |0.31 |trace|
|        |            |portal       |         |      |     |     |
|----------------------------------------------------------------|
|G0750913|chip/channel|56 m south of|1196     |0.3   |6.38 |1.6  |
|        |            |portal       |         |      |     |     |
|----------------------------------------------------------------|
|G0750914|chip/channel|86 m south of|1215     |0.7   |0.02 |trace|
|        |            |portal       |         |      |     |     |
|----------------------------------------------------------------|
|G0750915|chip/channel|100 m south  |1224     |0.55  |1.24 |1.1  |
|        |            |of           |         |      |     |     |
|        |            |portal       |         |      |     |     |
|----------------------------------------------------------------|
|G0750916|chip/channel|113 m south  |1229     |0.4   |34.1 |24.0 |
|        |            |of           |         |      |     |     |
|        |            |portal       |         |      |     |     |
|----------------------------------------------------------------|
|G0750917|chip/channel|113 m south  |1229     |0.3   |72.4 |33.9 |
|        |            |of           |         |      |     |     |
|        |            |portal and   |         |      |     |     |
|        |            |3m north     |         |      |     |     |
|        |            |of G0750916  |         |      |     |     |
------------------------------------------------------------------

The fault structures that host the mineralized quartz veins are intensely sheared and pervasively carbonatized along their margins, locally containing disseminated sericite near the vein contacts.

The quartz veins appear to be of two generations: a nearly barren phase with few mineralized fractures, and a sulphide-rich phase bordering the wall rock that contains disseminated to semi-massive pyrite plus local chalcopyrite that contains gold and silver. The mineralized quartz phase occurs as shoots or pods in the footwall or hanging wall side of the vein/fault. The property is underlain by the early to middle Jurassic Hazelton Group consisting mostly of intermediate volcanics and the Kleanza Pluton intrusives, dominantly andesite and diorite, respectively. These rocks have been intruded by younger, more granitic phases and by post-mineral dykes that parallel and crosscut the veins.

Surface drill results released in September, 2011 contain the same vein/fault zones sampled at surface thereby extending the potential for precious metal shoots below the historic mine workings (Table 4 and Argonaut News Release, Sept. 30, 2011).

Argonaut's President Ray Cook states: "The Company is delighted with the location and verification of numerous gold and silver bearing veins with our first look at the Columario property. Continued drill exploration may lead to the discovery of wider mineralized vein/fault zones that would additionally enhance the property potential."

TABLE 4. SURFACE DRILL RESULT HIGHLIGHTS


----------------------------------------------------------------------
|Drill    |Drill|Azimuth°/Dip°|Interval|Width|True |Au   |Ag   |*Vein|
|Hole     |Pad  |             |        |     |Width|(g/t)|(g/t)|     |
|         |     |             |(m)     |(m)  |(m)  |     |     |     |
|--------------------------------------------------------------------|
|COL11-05 |2    |240/-50      |42.5 –  |1.4  |1.1  |0.74 |2.8  |7    |
|         |     |             |43.9    |     |     |     |     |     |
|--------------------------------------------------------------------|
|Including|2    |             |42.5 –  |0.2  |0.15 |3.16 |11.2 |7    |
|         |     |             |42.7    |     |     |     |     |     |
|--------------------------------------------------------------------|
|COL11-14 |3    |345/-75      |39.5 –  |2.05 |1.3  |8.55 |27.1 |4    |
|         |     |             |41.55   |     |     |     |     |     |
|--------------------------------------------------------------------|
|Including|3    |             |40.0 –  |0.2  |0.13 |85.2 |272.0|4    |
|         |     |             |40.2    |     |     |     |     |     |
|--------------------------------------------------------------------|
|COL11-17 |4    |215/-45      |52.5 –  |0.45 |0.41 |2.39 |7.9  |5    |
|         |     |             |52.95   |     |     |     |     |     |
|--------------------------------------------------------------------|
|Including|4    |             |52.65 – |0.3  |0.27 |3.49 |11.4 |5    |
|         |     |             |52.95   |     |     |     |     |     |
|--------------------------------------------------------------------|
|COL11-17 |4    |215/-45      |102.0   |0.9  |0.82 |2.95 |9.5  |4    |
|         |     |             |-102.9  |     |     |     |     |     |
|--------------------------------------------------------------------|
|Including|4    |             |102.5 – |0.2  |0.18 |10.35|34.1 |4    |
|         |     |             |102.7   |     |     |     |     |     |
|--------------------------------------------------------------------|
|COL11-19 |4    |165/-45      |115.2 – |0.6  |0.34 |2.72 |6.4  |5    |
|         |     |             |115.8   |     |     |     |     |     |
|--------------------------------------------------------------------|
|Including|4    |             |115.5 – |0.15 |0.09 |8.81 |21.6 |5    |
|         |     |             |115.65  |     |     |     |     |     |
|--------------------------------------------------------------------|
|COL11-20 |4    |190/-45      |47.0    |0.8  |0.69 |0.85 |2.6  |5    |
|         |     |             |-47.8   |     |     |     |     |     |
|--------------------------------------------------------------------|
|COL11-20 |4    |             |103.15  |2.75 |2.11 |2.86 |8.3  |4    |
|         |     |             |-105.9  |     |     |     |     |     |
|--------------------------------------------------------------------|
|Including|4    |             |104.25  |0.35 |0.27 |15.36|44.6 |4    |
|         |     |             |-104.6  |     |     |     |     |     |
|--------------------------------------------------------------------|
|Including|4    |             |104.5 – |0.1  |0.08 |52.8 |148.0|4    |
|         |     |             |104.6   |     |     |     |     |     |
----------------------------------------------------------------------

* Apparent Vein

About Argonaut Exploration Inc.

Argonaut is a junior mineral exploration company focused on the acquisition, exploration and development of mineral properties. Argonaut owns 100% interest in 20,286 hectares of mineral tenures in the Terrace district and 7,832 hectares in the Terrace/Smithers district. The tenures include: the adjoining Columario and Bornite Range properties (18,683 hectares), the Fiddler-Dorreen property (1,602 hectares) located 15 km to the northwest and the High Gold copper-molybdenum porphyry property (7,832 hectares) located 48 km northeast. Gold, silver and copper veins are well documented on all of these properties.

For more information on the Corporation visit our website at www.argonautexploration.com.

For more information contact:

Dale HansenorRay Cook

CFO, DirectorPresident & CEO

Argonaut Exploration Inc.Argonaut Exploration Inc.

Tel: (403) 455-5641Tel: (403) 969-7903

Email: [email protected]: [email protected]

Argonaut Exploration Inc. has 32,438,139 shares issued and outstanding with an experienced management team. The Company trades on the TSX Venture Exchange, trading symbol AGA.

John Nebocat P. Eng., PGS Pacific Geological Services, is a qualified person as defined by National Instrument 43-101 and has reviewed and approved the technical information in the News Release. Analytical results are provided by ALS Canada Ltd of Vancouver, British Columbia. All core and rock samples were digested by a four acid leach followed by a 33 element ICP analysis. High ends were assayed. Gold was determined separately using a 30 gram sample split treated by fire assay with an ICP-AES finish. Gold results greater than 1 gram were re-analyzed using a 30 gram sample split and treated by fire assay with a gravimetric finish.

Forward - Looking Statements

Except for the statements of historical fact contained herein, certain statements contained in this news release constitute "forward-looking statements" as such term is used in applicable Canadian and US laws. These statements relate to analyses and other information that are based on forecasts of future results and assumptions of management. Any statements that express or involve discussions with respect to predictions, expectations, beliefs, plans or future events or performance (often, but not always, using words or phrases such as "expects" or "does not expect", "is expected", "anticipates" or "does not anticipate", "plans", "estimates" or "intends", or stating that certain actions, events or results "may", "could", "would", "might" or "will" be taken, occur or be achieved) are not statements of historical fact and should be viewed as "forward-looking statements". Such forward-looking statements, including but not limited to, potential drilling targets, exploration results, the timing of future diamond drilling and the Corporation's financial capacity to complete such operations , involve known and unknown risks, uncertainties and other factors which may cause the actual results, performance or achievements of the Corporation to be materially different from any future results, performance or achievements expressed or implied by such forward-looking statements.

Such risks and other factors include, among others: the timing and actual results of exploration activities; the availability of capital to fund exploration activities and the resulting dilution caused by the raising of capital through the sale of shares. Although the Corporation has attempted to identify important factors that could cause actual actions, events or results to differ materially from those described in forward-looking statements there may be other factors that cause actions, events or results not to be anticipated or intended. There can be no assurance that such statements will prove to be accurate as actual results and future events could vary or differ materially from those anticipated in such statements.

Forward-looking statements are made based on management's beliefs, estimates and opinions on the date the statements are made and the Corporation undertakes no obligation to update forward-looking statements if these beliefs, estimates and opinions or other circumstances should change, except as required by applicable law